Our wide range of products includes Field Communicator, Pressure transmitters, Temperature transmitters, Flow Meters, DCS etc.

8C-SHEDA1 | Series 8 Header Board

  • Specifications


    Experion Series 8 · Cabinet header board
    Power + IOLink · not an I/O module

    8C-SHEDA1 — Honeywell Series 8 Header Board (24 V Power and IOLink Distribution)

    8C-SHEDA1 is the Series 8 Header Board. That is the name Honeywell uses in S803-150-520, section 5.2 — not “system component,” and not a digital output spare. The board sits in the power-distribution path of the cabinet: it takes 24 VDC from the Series 8 power system and fans that power, together with IOLink, out to columns of mounting plates. Each IOTA in those columns receives power and IOLINK through a combination power / IOLink cable that starts at this header. HKXY Instruments can source the exact code as a trading company with 15 years of export experience; we do not manufacture the board and we do not publish stock or price on this page.

    Header-board identity

    Item Documented reference
    Manufacturer Honeywell
    Exact model 8C-SHEDA1
    Honeywell description Series 8 Header Board (S803-150-520 §5.2.2; confirmed again in S803-150-530 §5.2.2)
    Function Distribute 24 VDC and IOLink through the cabinet; extend power and IOLink to an adjacent cabinet
    Power input / output 24 VDC in, 24 VDC out
    Power connectors 3
    Combination cable connectors 4 pairs, 6 pins
    IOLINK extension 2 pairs, 3 pins
    Ambient temperature 0 to 60 °C
    Redundancy note One pair of header boards can provide redundant power and I/O communication
    Material number [TO CONFIRM] from the nameplate

    How the header relates to IOTAs — and what it is not

    The specification is explicit about the cable path: the IOTA does not take cabinet power from a random terminal strip; it receives power and IOLINK through the combination cable coming from the header. Those combination cables are daisy-chained so that unplugging one IOTA does not drop the remaining modules on the same run. The later S803-150-530 issue of the same specification also lists two Combo IOLINK 6-drop cables used with this header: 51202971-102 (grey) and 51202971-112 (violet). Confirm which colour and length are installed before treating a cable as a matching spare.

    Because the header is a cabinet distribution assembly, it is the wrong spare for a failed IOP or IOTA. It will not replace 8C-TCNTA1 (the C300 controller IOTA), a digital output termination, or a process I/O module. Live pages that grouped 8C-SHEDA1 with 8C-TDODA1 or 8C-PDODA1 were mixing a power/communication header with discrete output hardware. Those links are removed.

    Inquiry details for a header-board spare

    • Photograph the header nameplate and note whether a second 8C-SHEDA1 is already fitted for redundant distribution.
    • Identify which combination-cable run (and, if known, grey versus violet 6-drop cable) feeds the affected column.
    • State whether the need is a header replacement, a cable, or both — they are different line items.
    • Describe the cabinet position (same cabinet as the power system, or an extension into an adjacent cabinet).
    • Condition, packing, lead time, and price stay [TO CONFIRM].

    Related Series 8 cabinet hardware

    • 8C-TCNTA1 — C300 controller IOTA that receives power and IOLINK through the header path
    • 8C-PCNT03 — Series 8 C300 controller module mounted on that IOTA
    • Combination IOLINK 6-drop cables 51202971-102 (grey) and 51202971-112 (violet), as listed in S803-150-530 — confirm the installed part before ordering
    • Experion spare overview

    FAQ

    Is 8C-SHEDA1 an I/O module?
    No. Honeywell lists it under Series 8 power systems and accessories as the Header Board that distributes 24 V and IOLink.

    Do I need one or two header boards?
    A single header can feed columns in the cabinet. The specification states that one pair of header boards can provide redundant power and I/O communication. Match the installed arrangement.

    Will a header board replace a failed IOTA?
    No. The IOTA still has to be the correct model for the IOP or controller. The header only feeds power and IOLINK to those assemblies.

    Are the combination cables included with 8C-SHEDA1?
    Not on the evidence used for this page. S803-150-530 lists the 6-drop combo cables as separate part numbers. Ask for the cable code if a lead is damaged.

    Why were digital output pages removed from this article?
    8C-TDODA1 and 8C-PDODA1 are 24 V digital output hardware. They are not substitutes for a header board.

    Request a quote for 8C-SHEDA1

    Send a photograph of the header nameplate, note whether the cabinet already uses a redundant pair, and list any combination-cable part numbers on the run. HKXY Instruments will verify condition, inspection, packing, and lead time. We are not Honeywell.

    Contact: Vicky · 86-18086430982 · vicky@hkxytech.com
    TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG

    Request quote for 8C-SHEDA1

    Have any question, Please enter the form below and click the submit button.


    *
    *
    5 + 6 = ?
    Please enter the answer to the sum & Click Submit to verify your registration.
    CATEGORY AND TAGS:

    Honeywell

    Related Items

  • Product Categories

  • Why Us?

    1. 100% original product, 100% quality assurance.

    2. Varied payment methods.

    3.Safe & High-efficient shipping

  • Contact Us




    Contact: Vicky

    Mobile Phone: 86-18086430982
    Mail:vicky@hkxytech.com

    Address: TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG