CC-TAIM01 — Honeywell Series C PMIO Low-Level Multiplexer IOTA (for CC-PAIM01)
CC-TAIM01 is the 6-inch Input/Output Termination Assembly documented for Honeywell’s PMIO low-level temperature multiplexer. The electronics that plug onto it are CC-PAIM01. This page is therefore about the wiring base that connects the IOP to PMIO LLMUX field termination assemblies — not about a 16-channel 4–20 mA analog input card. HKXY Instruments is a China industrial automation trader with 15 years of export experience, not the OEM.
Product identity
| Item | Reference |
|---|---|
| Manufacturer | Honeywell |
| Exact model | CC-TAIM01 |
| Honeywell description | PMIO LL Mux IOTA, 6 inch |
| Mate IOP | CC-PAIM01 low-level temperature multiplexer (up to 64 channels) |
| Redundancy | Documented as the non-redundant 6-inch IOTA for this multiplexer pair |
| Material number | [TO CONFIRM] from the printed label (some catalogs list 51305959-175) |
What must be connected beyond the IOTA
Honeywell’s Series C I/O User’s Guide covers field wiring for Low Level Analog Input Mux IOTA model CC-TAIM01. The multiplexer does not land TC or RTD wires directly as if it were a high-level AI IOTA. Field sensors terminate on PMIO LLMUX FTAs, then cable to this IOTA:
- Mx-TAMR04 / MU-TAMR04 — 16 RTD inputs
- Mx-TAMT04 — 16 thermocouple or millivolt inputs
- Mx-TAMT14 — 16 TC/mV inputs with remote cold-junction reference
Up to four FTAs give the 64-channel ceiling. Replacing only CC-TAIM01 without checking FTA model, cable, and CJ method is a common cause of “module recognized / temperatures wrong” after a swap.
Why this is not a high-level AI IOTA
High-level 4–20 mA Series C analog inputs use families such as CC-TAIN01 / CC-TAIX01 / CC-TAID01 depending on HART and single-ended vs differential design. CC-TAIM01 exists only in the LLMUX row of Honeywell’s pairing table, next to CC-PAIM01. If the installed sensor is a 4–20 mA transmitter, this is the wrong spare.
RFQ checklist
- Photograph the CC-TAIM01 IOTA label and the plugged-in CC-PAIM01.
- List FTA models, how many are installed, and whether remote CJR (TAMT14) is used.
- Record cabinet slot, FTA cable identifiers, and sensor mix (TC types vs RTD curves).
- State whether you need the IOTA only or the IOTA-plus-IOP pair.
- Quantity and destination. Stock, price, and lead time are [TO CONFIRM].
Related Honeywell pages
Comparison only.
FAQ
Can CC-TAIM01 work without CC-PAIM01?
The IOTA is the mounting and wiring base. Process measurement still requires the CC-PAIM01 IOP and the correct PMIO FTAs.
Does this IOTA accept 4–20 mA transmitters?
That is not its documented role. Use the high-level analog input IOTA that matches the installed AI module.
Is there a redundant 12-inch version of this IOTA?
Honeywell’s pairing table shows CC-TAIM01 as the 6-inch PMIO LL Mux IOTA. Do not assume a TAIMxx redundant sibling without checking the official table for your release [TO CONFIRM if a later revision added one].
Where do the field wires land?
On the PMIO LLMUX FTAs (TAMR / TAMT families), not as if this were a standard 16-channel AI terminal strip.
Is pricing shown here?
No. Commercial terms are [TO CONFIRM].
Request pricing, inspection, and lead time
Include FTA model photos with the IOTA label so the quote covers the complete temperature-multiplexer path.
Contact: Vicky · 86-18086430982 · vicky@hkxytech.com
TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG
Verify via Honeywell Experion Series-C I/O Specification EP03-490-520 →