Our wide range of products includes Field Communicator, Pressure transmitters, Temperature transmitters, Flow Meters, DCS etc.

8C-TDODA1 | Series 8 Digital Output IOTA

  • Honeywell 8C-TDODA1 51307149-175 Digital Output Module

    Specifications


    Experion Series 8 · Digital output termination
    IOTA · 9 inch · bussed 24 V

    8C-TDODA1 — Honeywell Series 8 24 V Bussed Digital Output IOTA (9-Inch)

    The older supplier page on this site titled 8C-TDODA1 a “Digital Output Module” and printed material number 51307149-175 in the URL. That module wording is incorrect. S803-150-520’s model table and DO function matrix identify 8C-TDODA1 as the coated, 9-inch, non-redundant DO 24 V bussed IOTA — the termination that the digital output IOP plugs into. The electronics module is 8C-PDODA1, a 32-channel bussed 24 V digital output IOP already rewritten on its own page. These two parts work together; they are not the same spare. HKXY Instruments is a trading company, not Honeywell, and 51307149-175 remains [TO CONFIRM] until it is read from a nameplate.

    IOTA identity — what this board actually is

    Item Specification entry (S803-150-520)
    Manufacturer Honeywell
    Exact model 8C-TDODA1
    Honeywell description DO 24 V bussed IOTA, non-redundant, coated, 9 inch
    IOP that mounts here 8C-PDODA1 only, in the DO function matrix
    Redundant sibling 8C-TDODB1, 12-inch redundant DO 24 V bussed IOTA
    Optional accessory Relay extension board 8C-SDOX01 (15 inch) connects with the DO IOM and IOTA when dry-contact outputs are required — a separate assembly
    Fusing note that belongs to the IOTA Section 4.4.10, Note 1: short-circuit protection for each DO channel uses series fuses in the output channel. Four fuses on the DO IOTA cover the 32 channels.
    Field-power wiring option A wiring option on the IOTA determines whether outputs are referenced to Series 8 system power or to an external field power source (the isolation option applies only with user-supplied external power).
    Material 51307149-175 [TO CONFIRM] — present in the older URL and title, not verified from a nameplate here

    What you should not copy from the IOP page

    Ratings such as 100 mA per channel, 3.2 A per module, on-state voltage, off-state leakage, FAILOPT behaviour, and the detailed-table output type are properties of 8C-PDODA1. This page does not repeat that electrical table as if the IOTA were the IOP. Use the 8C-PDODA1 article when the failed part is the plug-in electronics. Use this article when the failed part is the 9-inch termination, including its output fuses or the field-power wiring option.

    A general Series 8 sizing rule in section 4.3 explains the length: a 32-point discrete function uses a 9-inch IOTA when non-redundant and a 12-inch IOTA when redundant. If the cabinet already has the 12-inch 8C-TDODB1, 8C-TDODA1 is the wrong board length. The IOTA also must not be confused with 8C-TDILA1 (digital input termination) or with 8C-SDOX01 (the relay extension).

    RFQ points for the termination, not the IOP

    • Photograph the IOTA nameplate and the fuses; confirm the printed code is 8C-TDODA1 rather than 8C-TDODB1 or 8C-PDODA1.
    • Say whether 8C-SDOX01 is cabled to this position, so the quotation is not silently treated as a relay-output spare.
    • Note system versus external field power, because that wiring option lives on the IOTA.
    • If the IOP is also required, list 8C-PDODA1 as a second line. Do not assume one part replaces the other.
    • Treat 51307149-175 as unconfirmed until it matches the label. Price and stock are not stated here.

    Related Series 8 digital output hardware

    • 8C-PDODA1 — 32-channel bussed 24 V digital output IOP that plugs into this IOTA
    • 8C-TDODB1 — 12-inch redundant DO IOTA for the same IOP
    • 8C-SDOX01 — optional 15-inch relay extension (separate assembly, confirm if present)
    • 8C-TDILA1 — digital input IOTA (contrast only; not a DO termination)

    FAQ

    Is 8C-TDODA1 a digital output module?
    No. Honeywell lists it as the 9-inch non-redundant DO 24 V bussed IOTA. The IOP is 8C-PDODA1.

    Where are the output fuses?
    On the IOTA. The specification says short-circuit protection uses series fuses, four fuses for 32 channels. A blown fuse is an IOTA-side issue, not a reason to assume the IOP is the only failed part.

    Does 51307149-175 have to appear on the quote?
    Only after it is read from the nameplate. The number in the older URL is [TO CONFIRM].

    Can I fit this IOTA into a redundant 12-inch cutout?
    No. The redundant board is 8C-TDODB1. Match the installed length.

    Is this the same as Series C CC-TDOB01 / CC-TDOB11?
    No. Those are Series C digital output IOTAs. Quote the Series 8 code on the installed board.

    Request a quote for 8C-TDODA1

    Send a photograph of the IOTA nameplate (and the IOP on it, if still fitted), and tell us whether the position is 9-inch non-redundant or 12-inch redundant, and whether a relay extension is used. HKXY Instruments will check condition, inspection, packing, and lead time. We are not the OEM.

    Contact: Vicky · 86-18086430982 · vicky@hkxytech.com
    TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG

    Request quote for 8C-TDODA1

    Have any question, Please enter the form below and click the submit button.


    *
    *
    5 + 7 = ?
    Please enter the answer to the sum & Click Submit to verify your registration.
    CATEGORY AND TAGS:

    Honeywell

    Related Items

  • Product Categories

  • Why Us?

    1. 100% original product, 100% quality assurance.

    2. Varied payment methods.

    3.Safe & High-efficient shipping

  • Contact Us




    Contact: Vicky

    Mobile Phone: 86-18086430982
    Mail:vicky@hkxytech.com

    Address: TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG