Our wide range of products includes Field Communicator, Pressure transmitters, Temperature transmitters, Flow Meters, DCS etc.

MTL 5500 Intrinsically Safe Isolators MTL5546Y


  • Delivery time:in stock

    Payment Terms: Paypal, Aliexpress, Western Union, T/T

    MOQ: 1pcs

    Specifications


    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    MTL4575 – MTL5575 TEMPERATURE CONVERTER THC or RTD input + Alarm
    The MTLx575 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safearea load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for all thermocouple types and 2-, 3- or 4-wire RTDs. (For thermocouple applications the HAZ-CJC plug on terminals 1–3 includes an integral CJC sensor). Configuration is carried out using a personal computer. A single alarm output is provided and may be configured for process alarm or to provide notice of early thermocouple failure.

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    MTL5546Y product specification

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    SPECIFICATION

    See also common specification

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Number of channels

    One
    Signal source
    THC types J, K, T, E, R, S, B or N to BS 60584 and XK
    mV input
    RTDs 2/3/4-wire platinum to BS 60751
    Pt 100, Pt 500, Pt 1000
    Cu-50 & Cu-53
    Ni 100/500/1000 DIN 43760

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Location of signal source

    Zone 0, IIC, T4-6 hazardous area
    Division 1, Group A, hazardous location

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Input signal range

    –75 to +75mV, or 0 to 400Ω (0 to 1000Ω Pt & Ni sensors)

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Input signal span

    3 to 150mV, or 10 to 400Ω (10 to 1000Ω Pt & Ni sensors)

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    RTD excitation current

    200µA nominal

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Cold junction compensation

    Automatic or selectable

     

    Cold junction compensation error

    ≤ 1.0°C

     

    Common mode rejection

    120dB for 240V at 50Hz or 60Hz (500ms response)

     

    Series mode rejection

    40dB for 50Hz or 60Hz

     

    Calibration accuracy (at 20°C)(includes hysteresis, non-linearity and repeatability)

    Inputs: (500ms response)
    mV/THC: ± 15µV or ± 0.05% of input value
    (whichever is greater)
    RTD: ± 80mΩ
    Output: ± 11µA

     

    Temperature drift (typical)

    Inputs:
    mV/THC: ± 0.003% of input value/°C
    RTD: ± 7mΩ/°C
    Output: ± 0.6µA/°C

     

    Example of calibration accuracy and temperature drift(RTD input – 500ms response)

    Span: 250Ω
    Accuracy: ± (0.08/250 + 11/16000) x 100%
    = 0.1% of span
    Temperature drift: ± (0.007/250 x 16000 + 0.6) µA/°C
    = ±1.0µA/°C

     

    Safety drive on sensor failure

    Upscale, downscale, or off

     

    Early burnout

    Early burnout detection for thermocouples (when selected)
    Alarm trips when loop resistance increase is > 50Ω

     

    Output range

    4 to 20mA nominal into 600Ω max.

     

    Alarm output (configurable)

    Relay ON in alarm, 250mA @ 35V max

     

    Maximum lead resistance (THC)

    600Ω

     

    Response time

    Configurable – 500 ms default
    (Accuracy at 100/200ms – contact MTL)

     

    LED indicator

    Green: power and status indication
    Yellow: alarm indication, on when contacts are closed

     

    Maximum current consumption (with 20mA signal)

    50mA at 24V

     

    Power dissipation within unit (with 20mA signal)

    1.2W at 24V

     

    Safety description

    Refer to certificate for parameters. Um=253V rms or dc

     

    Configurator

    A personal computer running MTL PCS45 software with a
    PCL45USB serial interface.
    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Other related product models for MTL5546Y as below for your reference.

    MTL5018AC
    MTL5501-SR
    MTL5510
    MTL5510B
    MTL5511
    MTL5513
    MTL5514
    MTL5514D
    MTL5516C
    MTL5517
    MTL5521
    MTL5522
    MTL5523
    MTL5523V – V
    MTL5524
    MTL5525
    MTL5526
    MTL5541
    MTL5541A
    MTL5541AS
    MTL5541S
    MTL5544
    MTL5544A
    MTL5544AS
    MTL5544D
    MTL5544S
    MTL5546
    MTL5546Y
    MTL5549
    MTL5549Y
    MTL5573
    MTL5575
    MTL5576-RTD
    MTL5576-THC
    MTL5581
    MTL5582
    MTL5582B
    MTL5991
    MTL5531
    MTL5532
    MTL5533
    MTL5561
    MPA5500
    MTL5051
    MTL5053
    MTL5314
    MTL5599
    MTL 5500 Intrinsically Safe Isolators MTL5546YWe are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC’s, etc.

    We mainly supply YOKOGAWA, Siemens, Honeywell , Rosemount, Endress Hauser, ABB, Weidmuller, ABB, MOELLER, Schneider Electic ,Omron ,Fluke ,PEPPERL+FUCHS,etc.

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Why choose us?

    1. 100% original product, 100% quality assurance.
    If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!

    2. Varied payment methods.
    We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!

    3. SHIPPING:
    We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
    It will take 3 to 7days to reach in your hands.

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Packaging:

    Imported with original packaging or standard export packing.Customize design is acceptable.

     MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Contact

    Wuhan Xieyuan Automation Equipment Co., Ltd
    Telephone:86-027-85583233
    Mobile Phone:86-18671080257
    Fax:86-027-85309780
    Contact:victor@whxyauto.com
    Skype:victordu963@gmail.com
    Whatsapp&Viber are available
    Address:7-A16,Caishen Commercial Plaza,Hankou Railway Station

    MTL 5500 Intrinsically Safe Isolators MTL5546Y

    Manufacturers supplied

    Have any question, Please enter the form below and click the submit button.


    *
    *
    3 + 8 = ?
    Please enter the answer to the sum & Click Submit to verify your registration.
    CATEGORY AND TAGS:

    MTL

    Related Items

  • Product Categories

  • Why Us?

    1. 100% original product, 100% quality assurance.

    2. Varied payment methods.

    3.Safe & High-efficient shipping

  • Contact Us




    Contact :Victor Du

    Mobile Phone:86-18671080257
    Mail:victor@hkxytech.com

    Address:7-A16,Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China