TC / RTD / mV · Up to 64 channels
CC-PAIM01 — Honeywell Series C Low-Level Temperature Multiplexer (LLMUX)
CC-PAIM01 is not a standard 16-channel 4–20 mA analog input card. Honeywell documents it as the Series C PMIO low-level multiplexer IOP: it collects thermocouple, millivolt, and RTD measurements through proven PMIO field termination assemblies. HKXY Instruments is a China industrial automation trader with 15 years of export experience, not the OEM. We help buyers verify the exact code, FTA mix, and IOTA before quotation.
Product identity
| Item | Reference |
|---|---|
| Manufacturer | Honeywell |
| Exact model | CC-PAIM01 |
| Honeywell description | PMIO LL Mux — low-level analog (temperature) input multiplexer |
| Paired IOTA | CC-TAIM01, 6-inch PMIO LL Mux IOTA |
| Channel capacity | Up to 64 inputs, added in 16-channel FTA increments |
| Material number | [TO CONFIRM] from the installed label |
How the temperature multiplexer is built
Per Honeywell Experion Series-C I/O Specification EP03-490-520, low-level inputs use Honeywell PMIO LLMUX FTAs. Each FTA supports 16 channels. Two FTA styles are documented:
- Mx-TAMR04 (also listed as MU-TAMR04 in the detailed multiplexer table) — 16 RTD inputs
- Mx-TAMT04 — 16 thermocouple or millivolt inputs
- Mx-TAMT14 — 16 TC/mV inputs with remote cold-junction reference
Any combination of those FTAs may be used so a cabinet can mix TC, mV, and RTD points. Temperature points are scanned at a fixed 1 second rate (up to 64 channels/s maximum as documented). All TC inputs are cold-junction compensated. Open thermocouple detection (OTD) can be configured so the open-sensor check occurs before the PV is propagated.
Documented LLMUX specifications
| Parameter | Specification |
|---|---|
| Input type | Thermocouple and/or RTD (plus millivolt via TC FTA) |
| Isolation | 64 fully isolated channels — channel-to-channel, channel-to-PM, and channel-to-power-supply common — in 16-channel increments |
| Nominal TC range | −20 to +100 mV |
| Channel bandwidth | 0 to 4.7 Hz (−3 dB) |
| Non-damaging continuous input | TC: −10 to +10 V; RTD: −1 to +2 V at 100 mA |
| Gain error (−20 to +100 mV) | 0.050% full scale maximum |
| Temperature stability | ±20 ppm/°C max for TC/mV and RTD |
| Long-term drift | 500 ppm |
Do not confuse with high-level analog input
CC-PAIN01 and CC-PAIH* modules accept 4–20 mA high-level signals on 16 channels. CC-PAIM01 is the temperature multiplexer path. Ordering the wrong IOP leaves the PMIO FTAs unmatched and the C300 database unable to map the points.
RFQ checklist
- Photograph the CC-PAIM01 nameplate and the CC-TAIM01 IOTA label.
- List every FTA model in the chain (TAMR04 / TAMT04 / TAMT14), cable lengths, and whether remote CJR is used.
- Record sensor types (TC type or RTD curve), quantity of points, and whether OTD is enabled.
- Note cabinet position, redundancy expectations, and Experion database export if available.
- Quantity, destination, and required date. Stock, price, and lead time remain [TO CONFIRM].
Related Honeywell pages
Comparison only — not approved substitutes.
FAQ
How many temperature points can one CC-PAIM01 support?
Up to 64, built from up to four 16-channel PMIO LLMUX FTAs.
Can one module mix RTD and thermocouple inputs?
Yes. Honeywell allows any combination of the documented RTD and TC/mV FTAs to create the required mix.
What IOTA must be ordered with it?
CC-TAIM01, the 6-inch PMIO LL Mux IOTA. The electronics module and IOTA should be treated as one assembly during replacement.
Is the scan time the same as a high-level AI card?
No. The LLMUX PV update is documented as 1 second, including the optional open-thermocouple check — much slower than a 50 ms high-level analog input scan.
Can you publish a live stock count or list price here?
No. Availability and commercial terms are [TO CONFIRM] after label verification.
Request pricing, inspection, and lead time
Include FTA models and a nameplate photo so we can quote the correct CC-PAIM01 assembly rather than a high-level AI lookalike.
Contact: Vicky · 86-18086430982 · vicky@hkxytech.com
TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG
Verify via Honeywell Experion Series-C I/O Specification EP03-490-520 →