Our wide range of products includes Field Communicator, Pressure transmitters, Temperature transmitters, Flow Meters, DCS etc.

MTL4561 2channel loop-powered, for fire and smoke detectors


  • Origin UK

    Payment Terms: Paypal, Aliexpress, Western Union, T/T

    MOQ: 1pcs

    Specifications


    MTL4561 2channel loop-powered, for fire and smoke detectors

    Eaton_MTL7700HONGKONG XIEYUAN TECH CO., LIMITED
    Telephone:86-027-85583233
    Mobile Phone:86-18671080257
    Fax:86-027-85309780
    Contact : victor@hkxytech.com
    Skype:victordu963@gmail.com
    Whatsapp & Viber are available
    Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station

    MTL 4500 Intrinsically Safe Isolators  MTL4561

    MTL4561 – MTL5561 FIRE AND SMOKE DETECTOR INTERFACE 2-channel The MTLx561 is a loop-powered 2–channel interface for use with conventional fire and smoke detectors located in hazardous areas. In operation, the triggering of a detector causes a corresponding change in the safe–area current. The unit features reverse input polarity protection.

    MTL4561 2channel loop-powered, for fire and smoke detectors

    The MTL4500 range is the latest generation of backplane mounting products, building upon the heritage of MTL4000 and introducing many key application benefits.

    SPECIFICATION
    See also common specification
    Number of channels
    Two, fully floating, loop powered
    Location of fire and smoke detectors
    Zone 0, IIC, T4–6 hazardous area if suitably certified
    Div. 1, Group A, hazardous area
    Input voltage
    6 to 30V dc
    Current range
    1 to 40mA, nominal
    Quiescent safe–area current at 20°C
    (hazardous–area terminals open circuit)
    < 400µA at Vin = 24V per channel
    Integral input polarity protection
    Input circuit protected against reverse polarity
    Minimum output voltage Vout at 20°C
    For Vin ≤ 25V: Vout = Vin – (0.38 x current in mA) – 2V
    For Vin > 25V: Vout = 22.5V – (0.35 x current in mA)
    Maximum output voltage
    28V from 300Ω
    Transfer accuracy at 20°C
    Better than 400µA
    Temperature drift
    < 4µA/°C ( 0°C to 60°C)
    < 15µA/°C (–20°C to 0°C)
    Response time to step input
    Settles to within 5% of final value within 1.5ms
    Power dissipation within unit
    0.7W maximum at 24V with 40mA signal (each channel)
    0.9W maximum at 30V with 40mA signal (each channel)
    Safety description for each channel
    Uo=28V Io=93mA Po=0.65W Um = 253V rms or dc

    MTL4561 2channel loop-powered, for fire and smoke detectors

    Improving upon the widely adopted, enormously successful, “industry standard” MTL4000 range was a big challenge but the innovative MTL4500 range includes several new features for backplane mounting isolating interfaces. This new family easily integrates with the I/O equipment of all major instrumentation and DCS suppliers in the same secure manner as its predecessor.

    intrinsically safe logo Symbol denotes that the equipment is suitable for use in hazardous area applications.
    fsm logo Symbol denotes that the product has been assessed for functional safety applications

    SM45-55-AI SM45-55-AI is FSM FSM Safety Manual – Analogue Input Modules
    SM45-55-AO SM45-55-AO is FSM FSM Safety Manual – Analogue Output Modules
    SM45-55-BI SM45-55-BI is FSM FSM Safety Manual – Binary Input Modules
    SM45-55-SAD SM45-55-SAD is FSM FSM Safety Manual – Solenoid / Alarm Driver Modules

    1. Intro
    INA4500 MTL4500 range Safety Instructions (ATEX)
    INM4500-4600 MTL4500/4600 Series Instruction Manual
    MTL4500-5500-ACC Backplanes, Enclosures & Accessories
    MTL4500-5500-CS Common Specification
    MTL4500-5500-DS MTL4500-5500 range Data Set

    2. Digital Input

    MTL4501-SR MTL4501-SR is intrinsically safe MTL4501-SR is FSM 1ch DI failsafe solid-state output + LFD alarm
    MTL4504 MTL4504 is intrinsically safe MTL4504 is FSM 1ch DI relay output + LFD alarm + phase reversal
    MTL4510 MTL4510 is intrinsically safe 4ch DI solid-state output
    MTL4510B MTL4510B is intrinsically safe 4ch DI multifunction solid-state output
    MTL4511 MTL4511 is intrinsically safe MTL4511 is FSM 1ch DI relay output
    MTL4513 MTL4513 is intrinsically safe 2ch DI solid-state output
    MTL4514D MTL4514D is intrinsically safe MTL4514D is FSM 1ch switch/prox input, dual output relay
    MTL4514_B MTL4514_B is intrinsically safe MTL4514_B is FSM 1ch DI relay output + LFD alarm
    MTL4516 MTL4516 is intrinsically safe MTL4516 is FSM 2ch DI relay output
    MTL4516C MTL4516C is intrinsically safe MTL4516C is FSM 2ch DI with changeover relay output
    MTL4517 MTL4517 is intrinsically safe MTL4517 is FSM 2ch DI relay output + LFD alarm

    3. Digital Output
    MTL4521 MTL4521 is intrinsically safe MTL4521 is FSM Loop powered solenoid driver
    MTL4521L MTL4521L is intrinsically safe MTL4521L is FSM loop powered solenoid driver IIC
    MTL4523 MTL4523 is intrinsically safe MTL4523 is FSM Solenoid driver with LFD
    MTL4523L MTL4523L is intrinsically safe MTL4523L is FSM Loop powered solenoid driver + LFD
    MTL4523R MTL4523R is intrinsically safe MTL4523R is FSM Solenoid driver with LFD
    MTL4523V – VL MTL4523V – VL is intrinsically safe MTL4523V – VL is FSM Solenoid/Alarm driver with voltage control
    MTL4524 MTL4524 is intrinsically safe MTL4524 is FSM Switch operated solenoid driver
    MTL4524S MTL4524S is intrinsically safe MTL4524S is FSM Switch operated solenoid driver, 24V override
    MTL4525 MTL4525 is intrinsically safe MTL4525 is FSM Switch operated solenoid driver low power
    MTL4526 MTL4526 is intrinsically safe 2ch switch operated relay

     

    4. Analogue Input

    MTL4541 MTL4541 is intrinsically safe MTL4541 is FSM 1ch 2/3 wire Transmitter repeater
    MTL4541A MTL4541A is intrinsically safe 1ch Transmitter repeater, passive input
    MTL4541AS MTL4541AS is intrinsically safe 1ch Transmitter repeater, passive input, current sink
    MTL4541B MTL4541B is intrinsically safe MTL4541B is FSM MTL4041B replacement
    MTL4541P MTL4541P is intrinsically safe MTL4041P replacement
    MTL4541S MTL4541S is intrinsically safe MTL4541S is FSM 1ch 2/3 wire Transmitter repeater, current sink

    MTL4541T MTL4541T is intrinsically safe 2/3 wire Transmitter repeater
    MTL4544 MTL4544 is intrinsically safe MTL4544 is FSM 2ch 2/3 wire Transmitter repeater
    MTL4544A MTL4544A is intrinsically safe 2ch Transmitter repeater, passive input
    MTL4544AS MTL4544AS is intrinsically safe 2ch Transmitter repeater, passive input, current sink
    MTL4544B MTL4544B is intrinsically safe MTL4044 replacement
    MTL4544D MTL4544D is intrinsically safe MTL4544D is FSM 2/3 wire transmitter repeater, dual output
    MTL4544S MTL4544S is intrinsically safe MTL4544S is FSM 2ch 2/3 transmitter repeater, current sink

     

    5. Analogue Output
    MTL4546 MTL4546 is intrinsically safe MTL4546 is FSM 1ch 4-20mA smart isolating driver + LFD
    MTL4546C MTL4546C is intrinsically safe MTL4546C is FSM 1ch 4-20mA smart isolating driver + oc LFD
    MTL4546S MTL4546S is intrinsically safe 1ch 4-20mA HART isolating driver + LFD
    MTL4546Y MTL4546Y is intrinsically safe MTL4546Y is FSM 1ch 4-20mA smart isolating driver + oc LFD
    MTL4549 MTL4549 is intrinsically safe MTL4549 is FSM 2ch 4-20mA smart isolating driver + LFD
    MTL4549C MTL4549C is intrinsically safe MTL4549C is FSM 2ch 4-20mA smart isolating driver + oc LFD
    MTL4549Y MTL4549Y is intrinsically safe MTL4549Y is FSM 2ch 4-20mA smart isolating driver + oc LFD

     

    6. Temperature Input

    MTL4573 MTL4573 is intrinsically safe 1ch Temperature converter, RTD / THC
    MTL4575 MTL4575 is intrinsically safe 1ch Temperature converter, RTD / THC with alarm
    MTL4576-RTD MTL4576-RTD is intrinsically safe 2ch Temperature converter, RTD
    MTL4576-THC MTL4576-THC is intrinsically safe 2ch Temperature converter, THC
    MTL4581 MTL4581 is intrinsically safe 1ch mV/THC isolator for low-level signals
    7. Pulse and Vibration
    MTL4531 MTL4531 is intrinsically safe 1ch vibration probe interface
    MTL4532 MTL4532 is intrinsically safe 1ch pulse isolator, digital or analogue output

     

    8. Fire and Smoke
    MTL4561 MTL4561 is intrinsically safe MTL4561 is FSM 2ch loop-powered, for fire and smoke detectors

     

    9. General
    MTL4599 Dummy isolator
    MTL4599N General purpose feed-through module

     

    HONGKONG XIEYUAN TECH CO., LIMITED
    Telephone:86-027-85583233
    Mobile Phone:86-18671080257
    Fax:86-027-85309780
    Contact : victor@hkxytech.com
    Skype:victordu963@gmail.com
    Whatsapp & Viber are available
    Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station

    Emerson Rosemount 475 field communicator

    Have any question, Please enter the form below and click the submit button.


    *
    *
    2 + 7 = ?
    Please enter the answer to the sum & Click Submit to verify your registration.
    CATEGORY AND TAGS:

    MTL

    Related Items

  • Product Categories

  • Why Us?

    1. 100% original product, 100% quality assurance.

    2. Varied payment methods.

    3.Safe & High-efficient shipping

  • Contact Us




    Contact: Vicky

    Mobile Phone: 86-18086430982
    Mail:vicky@hkxytech.com

    Address: TOWER 707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG