    Digital Input modules of MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    The Digital Input (DI) module range offers solid state or relay output switches in a safe area that respond to input switches located in a hazardous area. Single or multiple channel (2 or 4) options are available, as well as Line-Fault Detection (LFD).

    Modules with LFD can recognise open or short circuit conditions on the input wires going to the field sensors, and some DI modules have the facility to reverse the effect of the input on the output i.e. phase reversal.

    These options are chosen with switches located on the edge of the module on the hazardous area terminal side. In some applications it may be easier to set these switches before fitting the module to the DIN-rail.

     

    MTL5514 – switch/proximity detector interface  of MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

     

    Single channel, with line-fault detection and phase reversal

     

    The MTL5514 enables a safe-area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Line-Fault Detect and Phase Reversal for the channel are selected by DIL switches on the side of the module and output is provided by the changeover relay contacts.

     

    Channel 1 only switch settings apply.

     

    For switch sensor inputs, with LFD selected, make sure resistors (22kΩ and 680Ω) are fitted.

     

    Note: For reliable, long-term operation the load on the output switching relays should be not less than 50mW, e.g. 10mA at 5V DC.

     

     

    SPECIFICATION of MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

     

    Number of channels

    One

    Location of switch

    Zone 0, IIC, T6 hazardous area

    Div.1, Group A, hazardous location

    Location of proximity detector

    Zone 0, IIC, T4–6 hazardous area, if suitably certified

    Div.1, Group A, hazardous location

    Hazardous–area inputs

    Inputs conforming to BS EN60947–5–6:2001 standards for

    proximity detectors (NAMUR)

    Voltage applied to sensor

    7 to 9V dc from 1kΩ ±10%
     

    Input/output characteristics of MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    Normal phase

    Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

    Outputs open if input < 1.2mA (> 10kΩ in input circuit)

    Hysteresis: 200µA (650Ω) nominal

    Line fault detection (LFD) (when selected)

    User-selectable via switches on the side of the unit. Line faults

    are indicated by an LED. Line fault relay is energised and channel

    output relay de-energised if input line-fault detected

    Open-circuit alarm on if Iin < 50µA

    Open-circuit alarm off if Iin > 250µA

    Short-circuit alarm on if Rin < 100Ω

    Short-circuit alarm off if Rin > 360Ω

    Note: Resistors must be fitted when using the LFD facility with a contact input

    500Ω to 1kΩ in series with switch

    20kΩ to 25kΩ in parallel with switch
     

    Safe-area output of MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    MTL4514 & MTL5514

    Channel: Single pole relay with changeover contacts

    LFD: Single pole relay with changeover contacts

    MTL4514B

    Channel: Single pole relay

    LFD: Single pole relay

    Note: reactive loads must be adequately suppressed

     

    MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

     

    Models of MTL5500 Series :

    MTL5018AC

    MTL5501-SR

    MTL5510

    MTL5510B

    MTL5511

    MTL5513

    MTL5514

    MTL5514D

    MTL5516C

    MTL5517

    MTL5521

    MTL5522

    MTL5523

    MTL5523V – V

    MTL5524

    MTL5525

    MTL5526

    MTL5541

    MTL5541A

    MTL5541AS

    MTL5541S

    MTL5544

    MTL5544A

    MTL5544AS

    MTL5544D

    MTL5544S

    MTL5546

    MTL5546Y

    MTL5549

    MTL5549Y

    MTL5573

    MTL5575

    MTL5576-RTD

    MTL5576-THC

    MTL5581

    MTL5582

    MTL5582B

    MTL5991

    MTL5531

    MTL5532

    MTL5533

    MTL5561

    MPA5500

    MTL5051

    MTL5053

    MTL5314

    MTL5599

    MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC’s, etc.

    We mainly supply YOKOGAWA, Siemens, Honeywell , Rosemount, Endress Hauser, ABB, Weidmuller, ABB, MOELLER, Schneider Electic ,Omron ,Fluke ,PEPPERL+FUCHS,etc.

    MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

     

    Why choose us?

    1. 100% original product, 100% quality assurance.
    If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!

    2. Varied payment methods.
    We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!

    3. SHIPPING:
    We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
    It will take 3 to 7days to reach in your hands.

    MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    Packaging:

    Imported with original packaging or standard export packing.Customize design is acceptable.

     MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    Contact

    Wuhan Xieyuan Automation Equipment Co., Ltd
    Telephone:86-027-85583233
    Mobile Phone:86-18671080257
    Fax:86-027-85309780
    Contact:victor@whxyauto.com
    Skype:victordu963@gmail.com
    Whatsapp&Viber are available
    Address:7-A16,Caishen Commercial Plaza,Hankou Railway Station

    MTL5514 Switch Proximity Detector Interface With Line Fault Detection Alarm

    Manufacturers supplied

    Have any question, Please enter the form below and click the submit button.


    *
    *
    3 + 5 = ?
    Please enter the answer to the sum & Click Submit to verify your registration.
    CATEGORY AND TAGS:

    MTL

    Related Items

  • Product Categories

  • Why Us?

    1. 100% original product, 100% quality assurance.

    2. Varied payment methods.

    3.Safe & High-efficient shipping

  • Contact Us




    Contact :Victor Du

    Mobile Phone:86-18671080257
    Mail:victor@hkxytech.com

    Address:7-A16,Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China